<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>33623</ErrorNumber>
<ErrorFamily>Non-Volatile Storage</ErrorFamily>
<ErrorMessage>
STG: Invalid storage granularity
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_400_Fiber_Head_Machine</Text></ListItem>
<ListItem><Text>Lotem_800_Fiber_Head_Machine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>SAT_SNIF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
An invalid storage granularity is been used.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Run the "stg verify" command and reboot to try and recover from this condition.
If the problem persists, record the error number and report it, along with a
short description of the operation which caused the error to occur (if
possible), to Creo Service.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
A service that is required for configuration of the storage subsystem failed.
</Cause>
<Cause>
Flash is failing
</Cause>
<Cause>
The Nvs medium is corrupt or damaged.
</Cause>
<LastModified>
27-JAN-2002
Added detail.
</LastModified>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/stg_verify_flash.xml</LinkAddress><LinkTitle>Command: stg verify flash</LinkTitle></Link>
<Link><LinkAddress>../commands/stg_verify_ram.xml</LinkAddress><LinkTitle>Command: stg verify ram</LinkTitle></Link>
<Link><LinkAddress>../commands/stg_verify_temp.xml</LinkAddress><LinkTitle>Command: stg verify temp</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:22:59 2008 PST
</Updated>
<Links>
</Links>
</Error>
